Unit characteristics:
(1) Full air system, no cooling tower and water system required, no dedicated machine room required, greatly reducing initial investment.
(2) Simple and convenient on-site installation, simple and practical air conditioning method, greatly reducing labor management and equipment maintenance costs.
(1) Full air system, no cooling tower and water system required, no dedicated machine room required, greatly reducing initial investment.
(2) Simple and convenient on-site installation, simple and practical air conditioning method, greatly reducing labor management and equipment maintenance costs.
(3) The indoor unit adopts a large air volume and high static pressure design, and can adopt a long air duct branch air supply method to provide comfort to every corner of the room.
(4) In addition to adjusting the air temperature and humidity, the clean indoor unit can also purify the air to ensure indoor air quality.
(5) Fresh air can be introduced directly from the outdoors to improve indoor air quality and keep the indoor air fresh and hygienic. In transition seasons, fresh air can be used to operate, and the energy saving effect is more significant.
(6) You can choose a fresh air conditioning unit to ensure the freshness of indoor air to the greatest extent.
(7) Indoor air is directly cooled, reducing the energy loss of the intermediate media and improving the operating efficiency of the unit.
(8) The use of internationally renowned brand compressors makes the operation of the unit more reliable, durable and energy-saving. Its refrigeration efficiency is 12% higher than that of traditional piston compressors. The compressor has fewer moving parts, fewer repeated impacts, and low sliding speed, so it has high reliability and long life. It is suitable for the requirements of frequent switching cycles and long-term continuous operation in industrial air conditioning systems.
(9) The heat exchanger with excellent performance can provide strong cooling and heating capabilities even in bad weather. The staggered arrangement of copper tubes connected in series with aluminum fins not only provides sufficient air side disturbance and extremely high heat exchange efficiency, but also reduces air side resistance.
(10) The low-noise fan has undergone dynamic balance and static balance testing, and has low overall noise and small vibration . The fans and motors of the unit are selected according to the required air volume and pressure head. The fans are available in various types and perfectly match the unit's appearance design.
(11) The unit is equipped with multiple protections such as high and low pressure, motor overheating, and phase loss to ensure the reliable operation of the unit.
(12) The unit adopts microcomputer fully automatic control, and the control panel can be installed anywhere in the room to set the temperature and achieve scheduled operation and intelligent room control.
(13) The operation panel is beautiful and simple. Simple and easy-to-understand operating instructions enable users to understand the operation of the equipment at a glance, and set parameters quickly and easily.
(14) The outer casing is made of high-quality steel , and the panels are connected and spliced together to make the unit more secure, with low air leakage rate and complete protection of internal accessories. The overall structure of the unit is more compact and makes full use of the internal space of the box. It not only meets the requirements of the design specifications and ensures the user's use effect, but also makes the unit have a smaller appearance, thereby saving installation space for the user.